Coating Thickness Gauge - Dft Meter

Coating Thickness Pocket Gauge - Mp0r-fp

Ask Price

Coating Thickness Pocket Gauge - Mp0r-fp
  • Brand: Fischer
  • Weight: MP0R 137 g (4.8 oz), MP0R-FP 184 g (6.5 oz)
  • Power Supply: 2 Batteries, LR6, AA, 1.5 V
  • Brand: Fischer
  • Weight: MP0R 137 g (4.8 oz), MP0R-FP 184 g (6.5 oz)
  • Power Supply: 2 Batteries, LR6, AA, 1.5 V
  • USB port: 2.0 compatible, mini type B socket, for connecting a PC
  • Data transfer: Single readings, mean values, group separator
  • Admissible ambient: 0 to +40 Degree C (+32 to +104 Degree F)

Coating thickness pocket gauge – MPoR-FP is a pocket instrument consolidated with PC for suitable and rapid coating thickness measurement on all metals adequately. Coating thickness pocket gauge - MP0R-FP has proprietary conductivity compensation for calculation on non-magnetic substrate materials. Coating thickness pocket gauge - MP0R-FP is portable due to its hard-wearing structure and it also ensures that it never fails while working under unfavorable conditions. MPoR –FP is available for all our customers at standard price.



MODELS

DUALSCOPE MP0R: Probe integrated in the measuring instrument for single-handed operation

DUALSCOPE MP0R-FP: Probe with cable (80 cm; 31.5 “) permanently connected to the instrument, for measurements on various specimen shapes

Evaluation

 

Statistics:Display of mean value, standard deviation, MIN, MAX and number of

measurements per block


PC softwarePC software FISCHER DataCenter with the following functionality:

included inTransferring and archiving measurement data,comprehensive

the scope of supply:statistical and graphical evaluations, easy creation and printing

of inspection reports.


Measurement Functions

 

Block size:Adjustable between 2 and 20 single readings per block


Tolerance limits:Adjustable, depending on the selected measuring mode


Offset value:In the standard mode, the freely adjustable offset value is deducted

automatically from the measured value. Thus, one obtains the thickness

of the top coating if for instance the interim coating is known.


Units of measurement:Selectable μm or mils


Continuous display mode:Measurement in "continuous display mode" for continuous sampling

of the surfaces,e.g., in the manufacture of tanks and containers.


Normalization:Adaptation to the substrate material and the shape of the specimen.


Calibration:Factory calibration


Each individual instrument is factory calibrated at several reference points

with the greatest care to ensure the highest possible degree of trueness.


Corrective calibration (Adjustment)


Adaptation to the substrate material and the shape of the specimen and

to a thickness value using a calibration foil.


Simple Calibration


Adaption to the coating and substrate material in one step using a coated

reference part with a coating thickness higher than 200 μm (7.87 inches).

Nevertheless, this kind of calibration supplies only a lower accuracy as

specified in the sections Trueness and Repeatability Precision.

General Features

 

Measuring method:Magnetic induction method (ISO 2178, ASTM D7091, Measurement of

non-magnetic coatings on magnetic substrates)


Probe:Probe tip radius: 2 mm (78 mils); Probe tip material: Hard metal


Data memory:Max. 10,000 individual readings; the contents of the memory is retained

even without batteries


Measuring frequency:More than 70 measurements per minute


Measurement acquisition:Automatic upon placement of the probe; indication of the

 measurement with a beep visually with a green lit LED


Display:Graphic display, in addition to the measurement reading the mean value

 and the standard deviation or the number of measurement reading can also

 

 

know more